|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
DC-AC INVERTER UNIT CXA-0359(R) (8 W DUAL OUTPUTS WITH DIMMING FUNCTION) DESCRIPTION : This low profile DC to AC Inverter is developed for Dual lamps. NL10276BC24-13 (NEC) NL8060BC31-27 (NEC) NL8060BC31-28D (NEC) APPLICABLE LCD: 6.4 to 15 inches Dual lamp type Lamp Voltage 600 Vrms Lamp Current 5.0 mArms Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc) FEATURES : Dimming function Remote ON/OFF Open Lamp Detection RoHS compliant (R) Boost mode TEMPERATURE & HUMIDITY : Operating Temperature Range Storage Temperature Range Humidity DIMENSIONS : LxWxH (PRELIMINARY INFORMATION) -10C ~ +70C -30C ~ +85C 95 %RH max 120 x 25 x 8.5 mm 1200.3 (13) (10) (5) 820.1 (25) 1 1 CXA-0359 3303 MADE IN JAPAN 9,10 CN2 (10) SILICONE 1 250.3 150.1 CN1 1 IC2 (5) 8.5 max. (1.0) 65mm (a:High Voltage generation area) Note: Please use plastic screw in case of a non-insulating mounting base! Unit : mm Weight :23 (g) typ. Components No. 1 2 3 Part Description PCB Connector CN1 Connector CN2 Qty. 1 1 1 Material UL94V-0 (FR-4 or CEM-3) 53261-0990 SM03(7-D1)B-BHS-1-TB Note t=1m m Molex or equal JST or equal Power Systems - The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (1) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.2.1, 15th May 2007 All specifications are subject to change without notice. DC-AC INVERTER UNIT CXA-0359(R) (8 W DUAL OUTPUTS WITH DIMMING FUNCTION) Input side CN1: Pin No. Symbols Ratings Vin 11.4 ~ 12.6 Vdc CN 1-1+2 GND CN 1-3+4 Vrm t 0 ~ 0.4 = OFF/ 2.5 ~ Vin = ON CN 1-5 Vbr / Rbr1 CN 1-6 0 ~ 2.5 Vdc / 0 + 10 k Rbr2 CN 1-7 0 ~ 10 k Vs t 0 / 5 Vdc CN 1-8 (0 t o 0.4V : Low-mode (PRELIMINARY INFORMATION) Output side CN2: Pin No. Symbols Vhigh CN 2-1 Vhigh CN 2-2 N.C. CN 2-3 Vlow CN 2-4 Ratings 600 Vrm s (5.0 m Arm s ) 600 Vrm s (5.0 m Arm s ) (GND) CN 1-9 H/L 0V /5V 2 .5 t o V in : High-mode Open : Low-mode) ELECTRICAL CHARACTERISTICS : Low -mode Parameters Output Current Output Current Input Current Input Current Frequency Frequency (Duty) Open Circuit Voltage Alarm Signal Symbols Iout Iout Iin1 Iin2 F1 F2 Vopen Vs t Vin (V) 120.6 120.6 120.6 120.6 120.6 120.6 11.4 120.6 120.6 120.6 Conditions Vrmt Vbr (V) (V) 50.25 2.5 50.25 0 50.25 2.5 50.25 2.5 50.25 2.5 50.25 0 50.25 2.5 50.25 2.5 50.25 2.5 50.25 2.5 Specification Tu (C) -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 Min. Typ. 5.0 2.2 0.6 63 340 5.0 5.0 0 Max. 5.5 2.9 0.8 1 68 370 1800 5.5 5.5 0.5 Unit m Arm s m Arm s Adc m Adc kHz Hz Vrm s Vdc Vdc Vdc Note M ax M in ~ +70 4.5 ~ +70 1.5 ~ +70 ~ +70 ~ +70 58 ~ +70 310 ~ +70 1600 ~ +70 4.5 ~ +70 4.5 ~ +70 - Remo te of f RL1 Op en RL2 Open Normal High-mode Parameters Output Current Output Current Input Current Input Current Frequency Frequency (Duty) Open Circuit Voltage Alarm Signal Symbols Iout Iout Iin1 Iin2 F1 F2 Vopen Vs t Vin (V) 120.6 120.6 120.6 120.6 120.6 120.6 11.4 120.6 120.6 120.6 Conditions Vrmt Vbr (V) (V) 50.25 2.5 50.25 0 50.25 2.5 50.25 2.5 50.25 2.5 50.25 0 50.25 2.5 50.25 2.5 50.25 2.5 50.25 2.5 Specification Tu (C) -10 -10 -10 -10 -10 -10 -10 -10 -10 -10 Min. Typ. 7.0 3.5 0.8 63 340 5.0 5.0 0 Max. 7.5 4.0 1.0 1 68 370 2000 5.5 5.5 0.5 Unit m Arm s m Arm s Adc m Adc kHz Hz Vrm s Vdc Vdc Vdc Note M ax M in ~ +70 6.5 ~ +70 2.6 ~ +70 ~ +70 ~ +70 58 ~ +70 310 ~ +70 1800 ~ +70 4.5 ~ +70 4.5 ~ +70 - Remo te of f RL1 Op en RL2 Open Normal Note 1 : Note 2 : Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on mechanical drawing and any conductors. Two stages of dimming range of a Hi mode and a Low mode is selectable. Power Systems - The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (2) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.2.1, 15th May 2007 All specifications are subject to change without notice. DC-AC INVERTER UNIT CXA-0359(R) (8 W DUAL OUTPUTS WITH DIMMING FUNCTION) (PRELIMINARY INFORMATION) TEST CIRCUIT : SW1 a b Open Operation of unit Operation Non operation Operation SW2 a b Unit operation Voltage dim m ing Vbr= 0 ~ 2.5V (V b r=0V : M ax B rightness) Variable res is tance dim m ing Rbr= 0 ~ 10k (Rbr=0 : M ax B right ness) SW 3 a b Open Unit operation High-m ode (Lam p current 7m Arm s /Lam p) Low-m ode (Lamp current 5mA rms/ Lamp) Load condition Alarm output Shut-down function*2 Does not shut down Does not shut down Shut down Low-m ode (Lamp current 5mA rms/ Lamp) (CN1-8)*1 Normal condition 0.5V max. W hen one load 50.5V (lamp) is run-out W hen 2 loads 50.5V (lamps) is run-out *1: In the case of low mode, and more than one of SW4 - SW6 in the connection diagramm was open, alarm signal will output 5V. (Please make CN1-8 opening in a high mode) *2 : When all lamps were opened, this inverter has included protective function to stop operation in about 10 seconds Power Systems - The Power Solution Web: Email: www.Power-Systems.de Info@Power-Systems.de Page (3) Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany Tel. : + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 - 800 Version 1.2.1, 15th May 2007 All specifications are subject to change without notice. |
Price & Availability of CXA-0359 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |